230V to 24V/500mA
Thanks for you replies! But here's the thing. My product shall be mounted outside in a IP/NEMA enclosure. No power socket to use. Sure Jim, I need to take into account all the...
Friday, 19 March 2010 - 07:02
Xmega crystal not stable?
Hi again... solved it with this code: 32 MHz PLL driven by a 16 MHz crystal See attached file. I get Error 400 from AVR forum when trying to post the code. Would still be...
Tuesday, 23 February 2010 - 13:52
xmega and structs
Thanks for all the great replies guys! But there some to be a very basic problem. PA0 is not definied for the Xmega. Instead PIN0, PIN0_bm and PIN0_bp should be used. Or am I...
Monday, 22 February 2010 - 09:09
M-Bus and AVR
Yes I'm aware of that. But it's the only thread I found on the topic. I hope that any of them will be notified and reply back.
Tuesday, 9 February 2010 - 14:12
M-Bus and AVR
I'm intrested as well. Any success with a M-bus master for AVR? Kind regards Bjorn
Tuesday, 9 February 2010 - 10:40
Crystal selection for Xmega
Thanks for your replies! I notice that in table 7-5 C1/C2 is recommended to be 10 pF, which in somewhat lower then previous 22 pF. I guess for the internal CL for the crystal it...
Monday, 25 January 2010 - 10:53
Clearance for 230V design
Dear Paddy, Thank you for your extensive reply! I've already taken into account your last idea to buy a finished AD/DC power supply. But my power supply does not have a fuse, so...
Wednesday, 20 January 2010 - 08:35
Clearance for 230V design
Thanks for your replies. icarus1 wrote: There is a standard that defines thing like that. Just google for it. I've done that, found several pages. The problem is that no Google...
Wednesday, 20 January 2010 - 07:59
New version of Meshnetics SerialNet
Quote:These commands are +WNBSIZE and +WNB. Try them on devices in network. I cannot get the command +WNB to work. AT+WNB? just return ERROR. How is the syntax for this command?...
Wednesday, 16 September 2009 - 06:23
New version of Meshnetics SerialNet
Thanks for the reply! Quote:And I think there is unpublished commands to get neighbor table records. Would you be so kind to publish these commands? In order to determine how the...
Tuesday, 15 September 2009 - 05:46
New version of Meshnetics SerialNet
Yes, from the simple tests I've made. I can join nodes to the network and send data from C to R and back. That's the odd thing, that I can send data but still +WPARENT and +...
Wednesday, 9 September 2009 - 08:35
New version of Meshnetics SerialNet
Thanks Alexru for at quick reply! Could it be that I've just used the bootloader to download the SerialNet.srec? I.e, does the SerialNet.srec file include everything, including...
Wednesday, 9 September 2009 - 08:20